Dryer
tS - Thermistor Short: Indicates that the thermistor resistance is unexpectedly low. Check and clean the lint screen, ensure the vent system is not restricted, and measure the thermistor resistance.
tO - Thermistor Open: Triggered when the thermistor resistance is unusually high. Similar to the tS error, clean the lint screen, check for vent restrictions, and test the thermistor's resistance.
do - Door Open: The dryer detects that the door is open during operation. Ensure the door is properly closed before running the dryer and check for any issues with the door sensor circuit, including loose or disconnected wires.
FE - Power Source Frequency Error: Occurs when the dryer is not using the standard power source frequency. Verify that the power source and frequency are correct for your dryer.
dF - Door Circuit Failure: This error is reported when the door state is incorrect for more than 256 milliseconds. Inspect the door sensor circuit for loose or open wire terminals.
hE - Heater Error: Indicates a problem with heating, such as a restricted vent system or issues with the thermistor. Check for any obstructions in the venting and assess the thermistor.
bE - Button Error: Displays when a key on the dryer's control panel is shorted for 75 seconds. Check for a short in the display PCB's key circuit.
od - Over Dry: Reported when the dryer runs longer than the set drying time, potentially due to an open sensor bar or excessive time adjustments. Check the sensor bar and be cautious with time settings.
Et - EEPROM Communication Fail: Indicates a failure in EEPROM communication. This requires checking the PCB associated with the EEPROM circuit.